Skip to content

Learn More About Millrock Technology's Response to COVID-19 CLICK HERE

Freeze Dryer Comparison

Our freeze dryers / lyophilizers have been developed from over 50 years of experience in the freeze drying world. Our designs provide a highly reliable platform for your freeze dryer needs. Advanced system options include FreezeBooster® Controlled Nucleation, Auto-Dry™ Protocol Optimization, AccuFlux® Heat Flow Measurement and LyoPAT® In-Process, Process Analytical Technology. The combination provides the ideal platform for simplified and optimized protocol development.

Processing Tray Freeze Dryer Comparison

Laboratory and Commercial Freeze Dryers for Pharmaceutical Biotechnology Diagnostics Tissue Banks Scientific labs

Name Details
Freeze Dryer
Application
Usable Shelf Area
# of Shelves + Radiant Top Plate
Condenser Capacity
Condensing Rate
Condenser Temperature (Max low)
Refrigeration Cooling Requirements
Quanta
Production Freeze Dryers

8ft2 - 400ft2

0.75m2 - 37m2

Custom

Sized to Unit

Sized to Unit

-75C

Water

Small Production

15ft2 - 30ft2

1.39m2 - 2.78 m2

5 to 10

50L

40L/24 hrs

-85C

Water

MAGNUM XL®
Pilot Scale

20ft2 - 30ft2

1.85m2 - 2.78m2

10 to 15

30L

20L/24 hrs

-85C

Air
Standard / Water
Optional

MAGNUM®
Pilot Scale

10ft2 - 20ft2

1m2 - 1.85m2

5 to 10

30L

20L/24 hrs

-53 or -85C

Air
Standard / Water
Optional

REVO®
Lab Research & Development

2ft2 -10ft2

0.18 m2 - 1m2

1 to 5

30L

20L/24 hrs

-53 or -85C

Air
Standard / Water
Optional

STELLAR®
Lab

3.75 ft2 - 6.25ft2

0.35m2 - 0.58m2

3 to 5

12L

12L/24 hrs

-53 or -85C

Air

Name Details
QUANTA
Freeze Dryer
Application
Production Freeze Dryers
Usable Shelf Area

8ft2 - 400ft2
0.75m2 - 37m2

# of Shelves + Radiant Top Plate

Custom

Condenser Capacity

Sized to Unit

Condensing Rate

Sized to Unit

Condenser Temperature (Max low)

-75C

Refrigeration Cooling Requirements

Water

Name Details
Freeze Dryer
Application
Small Production
Usable Shelf Area

15ft2 - 30ft2
1.39m2 - 2.78 m2

# of Shelves + Radiant Top Plate

5 to 10

Condenser Capacity

50L

Condensing Rate

40L/24 hrs

Condenser Temperature (Max low)

-85C

Refrigeration Cooling Requirements

Water

Name Details
MAGNUM XL®
Freeze Dryer
Application
Pilot Scale
Usable Shelf Area

20ft2 - 30ft2
1.85m2 - 2.78m2

# of Shelves + Radiant Top Plate

10 to 115

Condenser Capacity

30L

Condensing Rate

20L/24 hrs

Condenser Temperature (Max low)

-85C

Refrigeration Cooling Requirements

Air
Standard / Water
Optional

Name Details
MAGNUM®
Freeze Dryer
Application
Pilot Scale
Usable Shelf Area

10ft2 - 20ft2
1m2 - 1.85m2

# of Shelves + Radiant Top Plate

5 to 10

Condenser Capacity

30L

Condensing Rate

20L/24 hrs

Condenser Temperature (Max low)

-53 or -85C

Refrigeration Cooling Requirements

Air
Standard / Water
Optional

Name Details
REVO®
Freeze Dryer
Application
Lab Research & Development
Usable Shelf Area

2ft2 -10ft2
0.18 m2 - 1m2

# of Shelves + Radiant Top Plate

1 to 5

Condenser Capacity

30L

Condensing Rate

20L/24 hrs

Condenser Temperature (Max low)

-53 or -85C

Refrigeration Cooling Requirements

Air
Standard / Water
Optional

Name Details
STELLAR®
Freeze Dryer
Application
Lab
Usable Shelf Area

3.75 ft2 - 6.25ft2
0.35m2 - 0.58m2

# of Shelves + Radiant Top Plate

3 to 5

Condenser Capacity

12L

Condensing Rate

12L/24 hrs

Condenser Temperature (Max low)

-53 or -85C

Refrigeration Cooling Requirements

Air

LyoPro Protocol Development Freeze Dryer Comparison

Protocol Development Freeze Dryers for Analysis, Optimization and Transfer

Name Details
Freeze Dryer
Application
Usable Shelf Area
# of Shelves + Radiant Top Plate
Condenser Capacity
Condensing Rate
Condenser Temperature
(Max low)
Refrigeration Cooling Requirements
Magnum Pro
Pilot Scale

10ft2 - 20ft2

1m2 - 1.85m2

5 to 10

30L

20L/24 hrs

-53 or -85C

Air
Standard/Water
Optional

Revo Pro
Lab Research & Development

2ft2 -10ft2

0.18 m2 - 1m2

1 to 5

30L

20L/24 hrs

-53 or -85C

Air
Standard/Water
Optional

MicroFD® with LyoSim & LyoPAT®
Small Research & Development

19in2

48.26cm2

1

0.5L

.5L/24 hrs

-70C

Air
Standard/Water
Optional

Name Details
Magnum Pro
Freeze Dryer
Application
Pilot Scale
Usable Shelf Area

10ft2 - 20ft2
1m2 - 1.85m2

# of Shelves + Radiant Top Plate

5 to 10

Condenser Capacity

30L

Condensing Rate

20L/24 hrs

Condenser Temperature (Max low)

-53 or -85C

Refrigeration Cooling Requirements

Air
Standard/Water
Optional

Name Details
REVO PRO
Freeze Dryer
Application
Lab Research & Development
Usable Shelf Area

2ft2 -10ft2
0.18 m2 - 1m2

# of Shelves + Radiant Top Plate

1 to 5

Condenser Capacity

30L

Condensing Rate

20L/24 hrs

Condenser Temperature (Max low)

-53 or -85C

Refrigeration Cooling Requirements

Air
Standard/Water
Optional

Name Details
MICROFD® WITH LYOSIM & LYOPAT®
Freeze Dryer
Application
Small Research & Development
Usable Shelf Area

19in2
48.26cm2

# of Shelves + Radiant Top Plate

1

Condenser Capacity

0.5L

Condensing Rate

5L/24 hrs

Condenser Temperature (Max low)

-70C

Refrigeration Cooling Requirements

Air
Standard/Water
Optional